⚡ NEC Quick Hit: Park Trailer Outlets & GFCIs (Part 3) ⚡
GFCI locations, 6-foot receptacle spacing rules, and panelboard clearances—let's review Sections 552.44 through 552.47! 👇
SLIDE 2 (RECEPTACLE SPACING & MANDATORY GFCIs)
Outlets and Protection:
The 6-Foot Spacing Rule: Receptacles must be installed at wall spaces 600 mm (2 ft) wide or more so no point along the floor line is over 1.8 m (6 ft) horizontally from an outlet. Face-up receptacles in countertops are strictly prohibited.
Mandatory GFCIs: Required for 125V, 15- and 20-ampere receptacles serving kitchen countertops, within 1.8 m (6 ft) of any sink or lavatory, inside toilet/shower/tub areas, and on the exterior of the unit.
Proximity Limit: Receptacles are banned within reach (750 mm / 30 in.) of a shower or bathtub space.
SLIDE 3 (PANELBOARDS & BRANCH CIRCUITS)
Panel Clearances and Circuit Caps:
Panel Accessibility: The panelboard must be in a readily accessible location with working clearances at least 600 mm (24 in.) wide and 750 mm (30 in.) deep.
Branch Circuit Limits: Park trailers can be equipped with a maximum of five 15- or 20-ampere circuits supplied by a 30-ampere rated feeder assembly (unless utilizing a listed energy management system). Six or more circuits require a 50-ampere feeder assembly.
SLIDE 4 (WRAP-UP) 💡 Apprentice Pro-Tip:
Receptacles installed for dedicated appliances like dishwashers, disposals, refrigerators, and freezers are exempt from interior GFCI rules under Section 552.41(C) Exception!